| Heat Meters - Heat Meter Series |
The electromagnetic flowmeter is a precision measuring product that meets the standard requirements. It has the characteristics of true full bore, low power consumption, high protection, etc. Based on the electromagnetic water meter, it is equipped with 2 Pt1000 to realize the function of cold and heat accumulation instrument. It has three modes of cold mode, heat mode, and automatic switching between cold and heat. The measuring instrument adopts a 32-bit MCU, advanced floating point calculation, and optimized filtering algorithm, which can quickly respond to changes and provide accurate measurement data. It can display real-time data such as the cold (heat) quantity, accumulated flow, instantaneous flow, inlet and outlet water temperature, temperature difference, and power of the measured medium on the full liquid crystal display.
Features Cold and heat accumulation meter: Combined with 2 Pt1000, it realizes the function of cold and heat accumulation meter, convenient for installation and reducing procurement and installation costs One instrument for multiple uses: It has three modes of cold quantity mode, heat mode, and automatic switching between cold and heat Advanced algorithm: It adopts a 32-bit MCU, advanced floating point calculation and optimized filtering algorithm, fast response, and accurate measurement data Screen display: LCD display, real-time display of the cold (heat) quantity, accumulated flow, instantaneous flow, inlet and outlet water temperature, temperature difference, power, etc. of the measured medium Password lock function: It has a digital password lock function to store parameters effectively to prevent unauthorized personnel from modifying instrument parameters Data storage: Supports 32 monthly accumulated reading reports and 32 power failure record reports Can simulate the measured signal in real time, greatly improving the efficiency of testing, debugging, and fault diagnosis Output interface: The output signal is standard RS-485 4-20mA, frequency/pulse output, with fast response, and the port design has anti-lightning and other protection measures Power supply method: Wide operating voltage range of (18-36)VDC and (85-240)VAC, suitable for various operating conditions
Parameters Measuring medium | Conducting liquid | Precision | ±0. 5% | Repeatability
| 0. 16% | Fluid temperature | (-25~200) °C | Conductivity
| ≥5μs/cm (softened water≥20μs/cm) | Caliber range | 3mm~2000mm | Working pressure | 0. 6MPa/l. 0MPa/1. 6MPa /2. 5MPa/ 4. 0MPa/Others | Velocity range
| (0. 5~10)m/s | Flow direction | Forward/reverse | Electrode material
| 316L/ Hastelloy C/ Titanium | Lining material
| Neoprene /PTFE/F46/PFA /PTFE/F46/PFA | Electrode form | Prescription electrode | Number of electrodes | four-electrode | Measuring pipe material | 304 stainless steel | Flange interface material | Carbon steel/Stainless steel | Installing form
| Flange | IP Grade | IP65/IP67/IP68 (customizable) | Power supply | 220VAC / 24VDC | Signal output | (4~20) mA/Bluetooth | Communication | Modbus Protocol/User-defined protocol | Electrical interface
| 1/2-14NPT / M20*l. 5 | Explosion-proof form | Non-explosion-proof/flameproof | Structural style | Monotype/ subtype | Straight pipe section requirements | First 5D after 3D |
|
|